View answer & solution
The paper uses the signed impedance angle: Z = R − jX_C, so tan φ = −X_C/R. (As a pure magnitude, the current leads by tan⁻¹(X_C/R).)
Every Network Theory question asked in RRB JE, GPSC DEE Electrical, GPSC AE Electrical, Supervisor Instructor and more — arranged topic by topic, with the exam and paper shown on each question.

The paper uses the signed impedance angle: Z = R − jX_C, so tan φ = −X_C/R. (As a pure magnitude, the current leads by tan⁻¹(X_C/R).)
In a parallel RLC circuit the source current is the phasor sum of I_R, I_L and I_C. The phase angle is the angle between the common voltage and that resultant current.
B — R + j0. A pure resistance has only a real part and zero imaginary (reactive) part; equivalently R∠0°.
An ideal inductor stores energy in its magnetic field and returns it to the source. Voltage and current are 90° apart, so the average real power over a complete cycle is zero.
The equivalent resistance is not simply R; it is obtained after adding the two admittances. Complex-conjugate multiplication gives |4+j3|²=25. Adding admittances cancels ±j3/25 exactly. Key relation: Yeq = 1/(4+j3)+1/(4−j3)=8/25=0.32 S; Zeq=1/Yeq=3.125 Ω; I=V/Zeq=32 A; PF=cos0°=1.
Exam focus: For parallel complex branches, convert Z to Y first; it prevents sign and denominator mistakes. Common trap: Directly adding parallel impedances or assuming the equivalent resistance equals the real part of each branch.
D — 1/Ztotal = 1/Z1 + 1/Z2. In a parallel circuit admittances add, so the reciprocal relation gives Ztotal = Z1Z2/(Z1 + Z2).
C — 4 A. The resistor and capacitor currents are 90° apart, so I² = IR² + IC² → IC = √(25 − 9) = 4 A.
C — The applied voltage. All branches of a parallel circuit are connected between the same two nodes, so they share the same voltage; branch currents differ.
D — Zero. In a pure capacitor current leads voltage by 90°, so P_avg = VI cos 90° = 0; energy is only stored and returned.
A — Zero. In a pure inductor the current lags the voltage by 90°, so power factor = cos 90° = 0 (zero lagging).
B — An inductive circuit. Net reactance X = X_L − X_C is positive, so current lags voltage.
For a coil Z = R + jωL. As ω → ∞, ωL dominates R, so the impedance becomes nearly purely inductive and the voltage leads current by 90°.
B — Z = R + j(X_L − X_C) Ω. In series, R, +jX_L and −jX_C add as complex quantities.
The phase difference identifies the element before any calculation: voltage is at +45° and current at −45°, so voltage leads current by 90°, which is the ideal-inductor relation. Then Xₗ = 628/10 = 62.8 Ω and L = Xₗ/ω = 62.8/314 = 0.2 H = 200 mH.
If a circuit response x depends linearly on independent sources u₁, u₂, …, then x(u₁+u₂+…) = x(u₁)+x(u₂)+…. Controlled/dependent sources stay in the circuit because their value is tied to another circuit variable; turning them off changes the network itself and destroys the correct controlling relationship.
Exam focus: When applying superposition, write “independent OFF, dependent ON” before starting the circuit reduction. Common trap: A very common error is to short/open a dependent source or to add individual source powers.
Superposition is a linear-circuit method used to find voltages or currents caused by multiple independent sources. Analyze one independent source at a time, replace other independent voltage sources by shorts and independent current sources by opens, and keep dependent sources active. Key relation: x = x₁ + x₂ + … for a linear response; P = V²/R = I²R is not a superposable quantity.
Exam focus: Deactivate only independent sources; never suppress a dependent source. Common trap: Adding powers from separate source cases is a classic trap.
The network is linear, so superposition can be used by analyzing the response to each sinusoidal source at its own frequency and then adding the time-domain currents. Because the two sources operate at different frequencies and the reactive impedances are frequency-dependent, a single phasor-domain source transformation cannot combine the complete problem without separate frequency analysis. Thus statement 1 is false and statement 2 is true.
Thevenin's theorem replaces a linear two-terminal network by one voltage source Vth in series with an equivalent impedance. For a network with independent sources, Rth/Zth is found by suppressing independent sources; dependent sources remain and may require a test-source method. Key relation: V_th=V_OC; Z_th seen at the port with independent sources suppressed.
Exam focus: In AC, use impedances—not just resistances. Common trap: Dependent sources are not turned off when finding Thevenin resistance.
B — Thevenin's theorem: V_th (open-circuit voltage) in series with R_th. Norton's theorem uses a current source in parallel instead.
A — Only linear, bilateral AC and DC circuits. Thevenin's theorem replaces a linear two-terminal network by an equivalent voltage source with a series resistance/impedance.
In AC, ZL must equal the complex conjugate of source/Thevenin impedance. At the resistive maximum-power point, half of the source power is dissipated internally, so efficiency is 50%. Key relation: DC: R_L=R_th. AC: Z_L=Z_th*.
Exam focus: Maximum power and maximum efficiency are different design objectives. Common trap: Do not claim the maximum-power condition minimizes circuit losses.
Source transformation preserves the terminal voltage-current behavior of a linear source-resistance pair. A voltage source Vs in series with R is equivalent to a current source Is=Vs/R in parallel with the same R, and conversely Vs=IsR. Key relation: Vs = Is R; Is = Vs/R.
Exam focus: Keep the resistance value unchanged when converting the source form. Common trap: Do not place the transformed resistor in the wrong series/parallel position.
The controlling current is signed: i_2 = −2 A. Hence v_x = 15i_2 = −30 V. The two source voltages add algebraically in the marked polarity, so v = v_x + 10 = −20 V.
All four branches share the same two nodes, so one node-voltage equation solves the circuit. Let the top-node voltage be V. Then i₀ = V/2, the dependent source current is i₀/4 = V/8 and the 8 Ω current is V/8. KCL gives V = 8 V, hence P₈Ω = V²/8 = 8 W.
C — One less than the number of nodes. After choosing one reference node, the remaining (n − 1) node voltages are the unknowns.
C — Kirchhoff's Current Law. Nodal analysis writes KCL at each non-reference node with node voltages as unknowns.
With iAB = 5 A, first determine the equivalent resistance seen between A and B from the resistor network. The network reduction gives approximately 6.842 Ω, so VAB = iAB Req ≈ 5 × 6.842 = 34.21 V.
For a connected network, the number of independent meshes is L = b - n + 1. If 4 mesh-current equations are required, 4 = b - n + 1, giving b = n + 3.
A — Super mesh. When a current source is shared by two adjacent meshes, they are combined into a supermesh and the source gives the constraint equation.
For a series RLC circuit, XL=XC at resonance, so the impedance is purely resistive and minimum, current is maximum, and power factor is unity. In an ideal parallel resonant circuit the input impedance is high, not minimum. Key relation: ω₀=1/√(LC); f₀=1/(2π√LC); at resonance XL=XC.
Exam focus: Series resonance: Z minimum, I maximum. Parallel resonance: input Z maximum (ideal case). Common trap: Reactive voltages can be large even though net reactive voltage is zero.
For a high-Q series RLC circuit, bandwidth is Δf = R/(2πL). With R=0.1 Ω and L=15 mH, Δf≈1.061 Hz. Half-power frequencies lie approximately symmetrically around 50 Hz, giving about 49.47 Hz and 50.53 Hz; the nearest option is 49.57 Hz and 50.53 Hz.
Electrical resonance occurs when the net reactive effect cancels. For a series RLC circuit, XL=XC at resonance, so the impedance is purely resistive and minimum, current is maximum, and power factor is unity. Key relation: ω₀=1/√(LC); f₀=1/(2π√LC); at resonance XL=XC.
Exam focus: Series resonance: Z minimum, I maximum. Parallel resonance: input Z maximum (ideal case). Common trap: Reactive voltages can be large even though net reactive voltage is zero.
A — As a purely resistive circuit. At series resonance X_L = X_C and they cancel, so Z = R (minimum) and current is maximum and in phase with voltage.
For a resonant network, bandwidth is inversely proportional to quality factor: BW = f₀/Q. Therefore a wider bandwidth requires a lower Q.
B — Q = ωL/R, with ω evaluated at resonance (ω = ω₀). The quality factor equals the voltage across either reactive component divided by the supply voltage at series resonance.
A is the intended option if the stated phase current of 10 A and the 440 V line voltage are used: P = √3 × 440 × 17.32 × 0.8 ≈ 10.56 kW. However, the supplied voltage, impedance and current are not mutually consistent.
A balanced three-phase system has three equal-magnitude phase quantities displaced by 120°. For a balanced load, the instantaneous total three-phase power is constant and the phasor sum of phase currents is zero, so a neutral conductor carries no current in the ideal balanced case. Key relation: P=√3 V_L I_L cosφ.
Exam focus: Balanced load ⇒ I_R+I_Y+I_B=0. Common trap: Do not apply zero-neutral-current result to unbalanced or harmonic-rich loads.
In a delta connection each phase is connected directly between two line conductors, so the phase voltage is exactly the line-to-line voltage: VL = Vph.
B — The load keeps working but becomes unbalanced. A delta has alternative paths between line terminals, so with one phase open it runs as open-delta (V-V) with reduced, unbalanced capacity.
A — Interchanging any pair of lines. Swapping two phase connections reverses their cyclic order and the direction of the rotating magnetic field.
D — The line currents are not equal. In delta, phase voltage = line voltage (balanced supply), but unequal branch impedances make phase and hence line currents unequal.
A first-order RC charging circuit responds exponentially because the capacitor voltage cannot change instantaneously. The time constant τ=RC sets the speed; at t=τ the capacitor reaches about 63.2% of its final voltage. Key relation: v_C(t)=V(1−e^(−t/RC)); i(t)=(V/R)e^(−t/RC); τ=RC.
Exam focus: One time constant = 63.2%; five time constants ≈ settled. Common trap: Charging current decreases with time; it does not increase toward steady state.
In a first-order RL circuit driven by a DC step, inductor current cannot change instantaneously. The time constant depends on both inductance and resistance, so changing either alters the transient speed. Key relation: i(t)=V/R·(1−e^(−t/τ)); τ=L/R.
Exam focus: Initial inductor current is continuous; final DC inductor acts as a short circuit. Common trap: Do not write τ=L alone; resistance is part of the time constant.
For an RL switching response i(t)=I∞+(I0+−I∞)e⁻ᵗ/τ, the given expression identifies I∞=2.5 A, the initial current as 4 A, and τ=1/4 s. Applying the pre-switch and post-switch DC equivalents and τ=L/Req gives R1=3 Ω and R2=5 Ω.
For an RL circuit the time constant is τ=L/R. It increases when inductance increases and when resistance decreases, because larger L resists current change while larger R dissipates energy faster.
Second-order dynamics are governed by two independent energy-storage states and are described by natural frequency and damping ratio. An underdamped response oscillates with exponentially decaying amplitude, critical damping gives the fastest non-oscillatory response, and overdamping gives a slower non-oscillatory response. Key relation: Characteristic form: s²+2ζω_n s+ω_n²=0.
Exam focus: ζ1 overdamped. Common trap: Overdamped responses do not sustain oscillations.
Damping is determined from the homogeneous second-order equation, not from the forcing term. Comparing s² + s + 1 with s² + 2ζωₙs + ωₙ² gives ωₙ = 1 rad/s and ζ = 0.5. Since 0 < ζ < 1, the series RLC response is underdamped and its natural response decays while oscillating.
For a linear two-port, terminal voltages are expressed in terms of terminal currents. Open-circuiting a port forces its current to zero and isolates the required coefficient. Key relation: V1 = Z11 I1 + Z12 I2; V2 = Z21 I1 + Z22 I2. Z11=(V1/I1)|I2=0, Z12=(V1/I2)|I1=0.
Exam focus: Memorize the condition “Z → open circuit (I=0)” and “Y → short circuit (V=0)”. Common trap: Do not label Z12=Z21 as symmetry; that equality is the reciprocity condition.
Z-parameters express two-port terminal voltages as linear combinations of port currents. Reciprocity requires Z12=Z21; symmetry additionally requires Z11=Z22. Key relation: V1=Z11I1+Z12I2; V2=Z21I1+Z22I2.
Exam focus: Reciprocal: Z12=Z21. Symmetric: Z11=Z22. Common trap: Do not confuse reciprocity with symmetry.
GPSC revised the final answer to option C. For Z-parameters, Z12 = V1/I2 with I1 = 0. With port 1 open, no current flows through the 10 Ω left series arm, so the voltage at port 1 equals the junction voltage produced by I2 through the 5 Ω shunt branch. Hence Z12 = 5 Ω.
KVL: the algebraic sum of voltages around a closed loop is zero. Here +10 − 6 − 4 = 0 V.
KCL follows from conservation of electric charge. In the lumped-circuit model, charge does not accumulate indefinitely at an ideal node, so the algebraic sum of currents entering and leaving the node is zero.
52 previous year Network Theory questions across 8 topics, each with the exam it was asked in, the verified answer and a step-by-step solution.
Supervisor Instructor · Part B Technical · 2026; GPSC DEE Electrical · DEE Master paper · 2026; GPSC AE Electrical · AE R&B · 2025 · Series M; GPSC DEE Electrical · DEE Electrical · 2024; RRB JE · CBT 2 Electrical · Shift 1 and more.
Yes. Tap “Download Network Theory PDF” — it is free after a quick sign-in and includes every answer and solution.