Electrical Machines MCQ – 65 previous year questions with solutions

Every Electrical Machines question asked in GPSC DEE Electrical, GPSC AE Electrical, Supervisor Instructor, Vidyut Sahayak JE and more — arranged topic by topic, with the exam and paper shown on each question.

65 PYQs7 topics7 papersFree PDF
Chapter practice0/65✓ 0✗ 0

DC Machines MCQs 19

Open DC Machines page →

DC Machines › Back EMF (4)

Q1Easy
A DC motor is supplied with 220 V and draws an armature current of 10 A.The armature resistance is 1 Ω. Then
1. The back EMF developed in the motor is approximately 210 V.
2. The electrical power converted into mechanical form is about 2100 W.
3. When load increases, the armature current increases and speed decreases.
4. The back EMF increases with increase in load current.
Which of the above statements is/are correct?
View answer & solution
Correct answer: B. 1, 2 and 3 only
Quick explanation

In a DC motor, back EMF is generated by armature rotation and opposes the applied supply. Eb=V−IaRa=220−10×1=210 V. Converted electromagnetic power≈EbIa=210×10=2100 W. Key relation: E_b=V−I_aR_a; P_converted≈E_b I_a; T∝ΦI_a.

Exam focus: Higher load → initially lower speed/Eb → higher armature current. Common trap: Do not say Eb rises simply because load current rises at constant supply.

Eb=V−I_aR_a; Pconverted≈Eb Ia; T∝ΦIa.
Verified · SRO editorial deskSolution page → Report
Q2Easy
How does induced emf in DC motor react to supply voltage?
View answer & solution
Correct answer: C. It will oppose the supply voltage
Quick explanation

The induced armature emf in a running DC motor is the back emf. By Lenz's law it opposes the applied supply voltage, limiting armature current as the motor gains speed.

V = Eb + Ia Ra Eb ∝ ΦN At start: N = 0 ⇒ Eb = 0
Verified · SRO editorial deskSolution page → Report
Q3Easy
At the instant of starting, how much back EMF is produced in a DC motor?
View answer & solution
Correct answer: A. Zero
Quick explanation

A — Zero. Back EMF is proportional to speed; at start the speed is zero, so Eb = 0 and the starting current is very high — hence a starter is needed.

Verified · SRO editorial deskSolution page → Report
Q4Easy
If the speed of a DC motor suddenly increases, what is the effect on back EMF?
View answer & solution
Correct answer: C. Back EMF increases as speed increases.
Quick explanation

C — Back EMF increases with speed. Eb = kΦN, so for constant flux back EMF is directly proportional to speed.

Verified · SRO editorial deskSolution page → Report

DC Machines › Armature Circuit (1)

DC Machines › Armature Reaction (1)

Q6Hard
A 400-V, 1000-A, lap wound DC machine has 10 poles, 860 armature conductors. The number of conductors in the pole face to give full compensation if pole face covers 70% of pole span is
View answer & solution
Correct answer: A. 3010
Quick explanation

For full compensation, the compensating ampere-turns under a pole face must cancel the armature ampere-turns in that region. Using the lap-wound armature data and 70% pole-arc coverage gives the keyed requirement of 3010 ampere-conductors/ampere-turn equivalent under the pole face.

Armature AT/pole = Z Ia /(2 A P) = 860×1000/(2×10×10) = 4300 AT/pole = 0.7×4300 = 3010
Verified · SRO editorial deskSolution page → Report

DC Machines › Armature Torque (1)

Q7Moderate
Assuming constant field flux, which condition increases the armature torque in a DC motor?
View answer & solution
Correct answer: B. Increasing the armature current
Quick explanation

B — Increasing the armature current. For a DC motor T ∝ ΦIa; with constant flux, torque rises directly with armature current.

Verified · SRO editorial deskSolution page → Report

DC Machines › Commutation (1)

Q8Easy
Consider the following statements regarding Commutation in DC Machines:
1. Commutation is the process by which alternating current in armature conductors is converted into direct current at the terminals.
2. Poor commutation results in sparking at the brushes and can damage the commutator surface.
3. Brush shifting and use of interpoles help in improving commutation performance.
4. Proper commutation is essential for efficient and sparkless operation of DC machines.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. All of the above
Quick explanation

During the short commutation interval, a coil is effectively short-circuited by the brush and its current must reverse from +I to −I. Interpoles are placed between main poles and connected so their flux produces a commutating emf of the required polarity. Key relation: Reactance voltage is associated with L·di/dt during current reversal; ideal commutation completes the reversal within the brush short-circuit time.

Exam focus: Keywords: commutation = current reversal; interpole = sparkless commutation. Common trap: Confusing the commutator with a source of DC; it is a mechanical switching/rectifying element.

Reactance voltage is associated with L·di/dt during current reversal; ideal commutation completes the reversal within the brush short-circuit time.
Verified · SRO editorial deskSolution page → Report

DC Machines › Compound DC Generator (1)

Q9Moderate
Which type of DC generator is most suitable for applications requiring automatic voltage regulation under changing load conditions?
View answer & solution
Correct answer: C. Compound DC generator
Quick explanation

C — Compound DC generator. The series field adds flux as load current rises, compensating the voltage drop of the shunt field, so terminal voltage stays nearly constant automatically.

Verified · SRO editorial deskSolution page → Report

DC Machines › DC Generator (1)

Q10Easy
Consider the following statements regarding DC Generators:
1. The generated EMF in a DC generator is directly proportional to both the speed of rotation and the magnetic flux per pole.
2. The field flux in a DC generator can be controlled by adjusting the field current in the excitation winding.
3. Armature reaction in a DC generator leads to distortion and weakening of the main magnetic field.
4. The commutator converts the internally generated alternating voltage into a unidirectional output voltage.
Which of the above statements is/are correct?
View answer & solution
Correct answer: B. 1, 2, 3 and 4
Quick explanation

The generated EMF of a DC machine is proportional to flux per pole and speed. Field flux is controlled by excitation current, armature reaction distorts/weakens the main field, and the commutator provides mechanical rectification so the external generated voltage is unidirectional. Key relation: E_g=PΦZN/(60A).

Exam focus: Remember A=2 for wave winding and A=P for simplex lap winding. Common trap: Do not swap the parallel-path counts for lap and wave windings.

Eg=PΦZN/(60A).
Verified · SRO editorial deskSolution page → Report

DC Machines › DC Generator EMF Equation (1)

Q11Moderate
In the EMF equation of a DC generator, what does Z represent?
View answer & solution
Correct answer: C. Total number of armature conductors
Quick explanation

C — Total number of armature conductors. In E = PΦZN/(60A), Z is the total number of armature conductors.

Verified · SRO editorial deskSolution page → Report

DC Machines › Direction of Rotation (1)

Q12Moderate
If both the direction of armature current and the direction of the magnetic field in a DC motor are reversed together, what will be the effect on the motor's direction of rotation?
View answer & solution
Correct answer: D. Direction of rotation will remain unchanged
Quick explanation

D — Direction of rotation remains unchanged. Torque T ∝ ΦIa; reversing both Φ and Ia leaves the sign of torque the same. Reverse only one of them to reverse rotation.

Verified · SRO editorial deskSolution page → Report

DC Machines › Generated EMF (1)

Q13Easy
If the armature of a DC generator rotates at half its normal speed, what happens to the generated EMF?
View answer & solution
Correct answer: A. It becomes half.
Quick explanation

A — It becomes half. E = PΦZN/(60A), so with constant flux the generated EMF is directly proportional to speed.

Verified · SRO editorial deskSolution page → Report

DC Machines › Open-Circuit Characteristic (1)

Q14Easy
The air gap line represents _________
View answer & solution
Correct answer: A. Magnetic behaviour of the air gap of the DC machine
Quick explanation

The air-gap line is the straight unsaturated reference line on a DC machine magnetization curve. It represents the magnetic behaviour when the reluctance is dominated by the air gap and iron saturation is neglected.

Φ ∝ If E0 ∝ Φω
Verified · SRO editorial deskSolution page → Report

DC Machines › Series Motor (1)

Q15Moderate
Consider following statements: Assertion: DC series motors are suitable for electric locomotives. Reason: DC series motors provide high starting torque. Of these statements:
View answer & solution
Correct answer: A. Both Assertion and Reason are true and Reason is the correct explanation of Assertion.
Quick explanation

A DC series motor develops very high starting torque because, before saturation, flux is approximately proportional to armature current and torque T∝ΦIa≈Ia². This makes it suitable for traction applications such as electric locomotives. Both assertion and reason are true, and the reason correctly explains the assertion: option A.

T∝ΦIa; unsaturated series motor Φ∝Ia → T∝Ia²
Verified · SRO editorial deskSolution page → Report

DC Machines › Speed Control (1)

Q16Easy
Ward leonard method of speed control is used because of:
View answer & solution
Correct answer: A. Fine speed control over whole range
Quick explanation

A — Fine speed control over whole range. The Ward Leonard system provides smooth DC motor speed variation by adjusting the generator output voltage.

N ∝ (Va − IaRa)/Φ N ∝ (Va − IaRa)/Φ
Verified · SRO editorial deskSolution page → Report

DC Machines › Testing of DC Series Motors (1)

Q17Moderate
_________ test is used for determining the efficiency of a traction motor.
View answer & solution
Correct answer: C. Field
Quick explanation

The field test is a regenerative/back-to-back test suited to DC series machines, including traction motors, and allows efficiency to be determined under load conditions without wasting full output power.

Verified · SRO editorial deskSolution page → Report

DC Machines › Torque Equation (1)

Q18Easy
A DC motor has flux = constant and armature current = 20 A.
1. Torque is directly proportional to armature current under constant flux condition.
2. If current doubles, torque also doubles.
3. Torque is independent of flux.
4. Torque depends on product of flux and current.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 4 only
Quick explanation

The electromagnetic torque of a DC motor is proportional to the product of air-gap flux and armature current. If flux is held constant, torque varies directly with armature current, so doubling current ideally doubles torque. Key relation: T=kΦI_a.

Exam focus: Constant flux converts the general torque equation into T∝I_a. Common trap: Do not generalize constant-flux behavior into 'torque is independent of flux'.

T=kΦIa.
Verified · SRO editorial deskSolution page → Report

DC Machines › Voltage Equation (1)

Q19Easy
The voltage equation of a DC motor is V = E + Ia Ra. What does E stand for in this equation?
View answer & solution
Correct answer: C. Back EMF
Quick explanation

C — Back EMF. As the armature of a running motor rotates in the magnetic field, an EMF is induced that opposes the applied supply voltage.

Verified · SRO editorial deskSolution page → Report

Transformers MCQs 16

Open Transformers page →

Transformers › Transformer Efficiency (3)

Q20Moderate
Consider the following statements regarding Transformer Efficiency:
1. The maximum efficiency of a transformer occurs when copper losses are equal to core losses.
2. Transformer efficiency remains constant irrespective of the load connected to it.
3. All-day efficiency is an important performance metric for distribution transformers.
4. Efficiency generally increases with load up to a certain point before decreasing.
Which of the above statements is/are correct?
View answer & solution
Correct answer: B. 1, 3 and 4 only
Quick explanation

Transformer core loss is approximately constant at fixed voltage/frequency, while copper loss is I²R and therefore varies with the square of load. The competition between these losses creates a definite maximum-efficiency load point. Key relation: At x p.u. load: Pcu=x²Pcu,FL. Maximum η when x²Pcu,FL = Pi. All-day η = output energy (kWh)/input energy (kWh).

Exam focus: Remember: power transformer → ordinary efficiency; distribution transformer → all-day efficiency is frequently tested. Common trap: Saying efficiency is constant because transformer has no moving parts.

At × p.u. load: Pcu=x²Pcu,FL. Maximum η when x²Pcu,FL = Pi. All-day η = output energy (kWh)/input energy (kWh).
Verified · SRO editorial deskSolution page → Report
Q21Easy
A transformer has core loss = 500 W and full-load copper loss = 500 W.
1. Maximum efficiency occurs at full load condition.
2. At half load, copper loss becomes 125 W.
3. Efficiency at half load is lower than full load efficiency.
4. Condition for maximum efficiency is that copper loss equals core loss.
Which of the above statements is/are correct?
View answer & solution
Correct answer: B. 1, 2, 3 and 4
Quick explanation

At x p.u. load, transformer output is proportional to x while copper loss is proportional to x² and iron loss remains approximately constant. The given losses make the maximum-efficiency load x=sqrt(500/500)=1 p.u. Every statement follows numerically, so B is correct. Key relation: Pcu(x)=x²Pcu,FL. Here Pcu(0.5)=0.25×500=125 W. Maximum η: x²Pcu,FL=Pi → x=1.

Exam focus: If core loss equals full-load copper loss, maximum efficiency is at full load—an instant result. Common trap: Scaling copper loss linearly with load instead of with load squared.

Pcu(x)=x²Pcu,FL. Here Pcu(0.5)=0.25×500=125 W. Maximum η: x²Pcu,FL=Pi → x=1.
Verified · SRO editorial deskSolution page → Report
Q22Easy
A two-winding transformer operates at maximum efficiency when ____________.
View answer & solution
Correct answer: C. copper loss = iron loss
Quick explanation

C — Copper loss = iron loss. Maximum efficiency occurs at the load where the variable copper loss equals the constant iron (core) loss.

Verified · SRO editorial deskSolution page → Report

Transformers › EMF Equation (2)

Q23Easy
What is the number of primary turns in a 200/1000V transformer if the emf per turn is 10V?
View answer & solution
Correct answer: C. 20
Quick explanation

The given transformer ratio is 200/1000 V and the emf per turn is 10 V. For the 200 V winding, N = E/(emf per turn) = 200/10 = 20 turns.

Emf per turn = E/N N = E / (emf per turn) N1 = 200/10 = 20 turns
Verified · SRO editorial deskSolution page → Report
Q24Moderate
In the EMF equation of a single-phase transformer E = 4.44 × f × N × φm, what does φm represent?
View answer & solution
Correct answer: D. Maximum magnetic flux in the transformer core
Quick explanation

D — Maximum magnetic flux in the core. In E = 4.44 f N φm, φm is the peak value of the sinusoidal core flux.

Verified · SRO editorial deskSolution page → Report

Transformers › Autotransformer Applications (1)

Q25Easy
A 2000/1000/500 three winding transformer is to be used as auto transformer with supply of 3000V. Two loads of 1050 kVA at 3500 V and other one at 180 kVA at 1000 V. The total kVA supplied will be
View answer & solution
Correct answer: A. 1230 kVA
Quick explanation

The two specified loads are 1050 kVA and 180 kVA. The total apparent power supplied to the loads is therefore 1050 + 180 = 1230 kVA, matching option A.

Stotal = S₁ + S₂ = 1050 + 180 = 1230 kVA
Verified · SRO editorial deskSolution page → Report

Transformers › Dry-Type Transformer (1)

Q26Easy
With reference to Dry-type Transformers in commercial buildings, consider the following:
1. They use air as the cooling and insulating medium instead of oil.
2. They are preferred for indoor installations due to reduced fire hazard.
3. They require frequent oil filtration and acidity testing.
Which of the statements given above is/are correct?
View answer & solution
Correct answer: A. 1 and 2 only
Quick explanation

Dry-type transformers use solid insulation and air/natural/forced-air cooling rather than flammable insulating oil. Their lower fire and environmental risk makes them suitable for indoor/commercial installations. Key relation: Cooling classes include AN/AF for dry-type designs.

Exam focus: Indoor fire-risk questions often favor dry-type transformers. Common trap: Oil maintenance belongs to oil-filled transformers, not dry-type units.

Verified · SRO editorial deskSolution page → Report

Transformers › Ideal Transformer (1)

Q27Easy
A single-phase transformer operates with primary voltage of 230 V and secondary voltage of 115 V. It supplies a load current of 4 A. Assume ideal conditions.
1. The turns ratio between primary and secondary is 2.
2. The primary current is 2 A.
3. The output power delivered to the load is 460 W.
4. The input power is greater than output power under ideal conditions.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 3 only
Quick explanation

An ideal transformer conserves apparent power and relates voltages, turns and currents inversely. Turns ratio a=230/115=2. Output power=115×4=460 W. Key relation: V1/V2=N1/N2=a; I1/I2=N2/N1=1/a; ideal V1I1=V2I2.

Exam focus: Voltage ratio follows turns ratio; current ratio is inverse. Common trap: In an ideal transformer input power equals output power.

V1/V2=N1/N2=a; I1/I2=N2/N1=1/a; ideal V1I1=V2I2.
Verified · SRO editorial deskSolution page → Report

Transformers › Isolation Transformer (1)

Q28Easy
The transformation ratio of an isolation transformer is usually:
View answer & solution
Correct answer: A. 1 : 1
Quick explanation

A — 1 : 1. A usual isolation transformer has equal primary and secondary turns so that it transfers approximately the same AC voltage while providing galvanic separation between the circuits.

Ideal transformer: V₂/V₁ = N₂/N₁. For equal turns, N₂ = N₁ and V₂/V₁ = 1.
Verified · SRO editorial deskSolution page → Report

Transformers › OC and SC Tests (1)

Q29Easy
While conducting open circuit test and short circuit test on a transformer, status of low voltage and high voltage windings will be such that in ____________
View answer & solution
Correct answer: A. OC test − h.v. open, SC test − l.v. short-circuited
Quick explanation

In the usual transformer tests, the open-circuit test is performed by energizing the LV side and leaving the HV side open. The short-circuit test is usually performed by shorting the LV side and applying a reduced voltage to the HV side. This matches option A.

Verified · SRO editorial deskSolution page → Report

Transformers › Parallel Operation (1)

Q30Moderate
Two single phase transformers A and B are operating in parallel having different impedance and identical x/r ratio. Then __________
View answer & solution
Correct answer: D. Both operate at same power factor
Quick explanation

If two transformers have different impedance magnitudes but identical X/R ratios, their impedance angles are equal. They may share unequal magnitudes of load, but the load-current phase angles are the same, so both operate at the same power factor.

ZA = |ZA|∠θ ZB = |ZB|∠θ (same X/R ⇒ same θ)
Verified · SRO editorial deskSolution page → Report

Transformers › Three-Phase Transformer Connections (1)

Q31Moderate
Which of the following is not a valid three phase transformer connection?
View answer & solution
Correct answer: A. Dd1
Quick explanation

A — Dd1. A conventional delta–delta transformer connection does not provide the 30° displacement required by clock number 1.

Clock displacement = clock number × 30° Dd1 requires 30°; conventional Dd does not provide this displacement Phase displacement = 1 × 30° = 30°
Verified · SRO editorial deskSolution page → Report

Transformers › Transformer Construction (1)

Q32Easy
What essential function is performed by the core in a single-phase transformer?
View answer & solution
Correct answer: D. It provides a magnetic path for flux linkage between the coils.
Quick explanation

D — It provides a magnetic path for flux linkage between the coils. The core gives a low-reluctance closed path to the alternating flux produced by the primary so that it links the secondary.

Verified · SRO editorial deskSolution page → Report

Transformers › Transformer Core Materials (1)

Q33Easy
The steel used for transformer core has:
View answer & solution
Correct answer: D. High permeability
Quick explanation

D — High permeability. A high-permeability core provides a low-reluctance path and establishes the required flux with comparatively little magnetizing current.

ℜ = l/(μA) NI = Φℜ Magnetic reluctance ℜ = l/(μA) Φ = NI/ℜ
Verified · SRO editorial deskSolution page → Report

Transformers › Transformer Tests (1)

Q34Easy
Consider the following statements regarding Transformer Testing:
1. The open-circuit test is conducted to determine core losses and magnetizing current at rated voltage conditions.
2. The short-circuit test is used to determine copper losses and equivalent impedance of the transformer.
3. In the open-circuit test, rated current flows in the primary winding during the test.
4. In the short-circuit test, a reduced voltage is applied to circulate rated current in the windings.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 4 only
Quick explanation

OC and SC tests separate transformer loss components without loading the transformer fully. OC emphasizes shunt/core behavior; SC emphasizes series/leakage behavior. Key relation: OC: P0 ≈ Pi(core). SC at rated current: Psc ≈ Pcu,FL; Zeq = Vsc/Isc; Req=Psc/Isc².

Exam focus: OC → rated voltage, small current, core loss. SC → rated current, small voltage, copper loss. Common trap: Confusing “rated voltage” in OC with “rated current”; the OC current is deliberately small.

OC: P0 ≈ Pi(core). SC at rated current: Psc ≈ Pcu,FL; Zeq = Vsc/Isc; Req=Psc/Isc².
Verified · SRO editorial deskSolution page → Report

Transformers › Turns Ratio (1)

Q35Easy
In a transformer, if the primary coil has more turns than the secondary coil, the output voltage from the secondary coil will be ________.
View answer & solution
Correct answer: A. less than the input voltage
Quick explanation

A — Less than the input voltage. In an ideal transformer V2/V1 = N2/N1; with N1 > N2 it is a step-down transformer.

Verified · SRO editorial deskSolution page → Report

Induction Motors MCQs 14

Open Induction Motors page →
Q36Easy
In a three-phase induction motor, the phasor diagram shows an angle between the applied stator voltage and the resulting stator current. This angle primarily indicates:
View answer & solution
Correct answer: C. Input power factor
Quick explanation

The angle φ between stator voltage and stator current is the power-factor angle; input power factor = cos φ.

Power factor = cos φ P_in = √3 V_L I_L cos φ
Verified · SRO Electrical deskSolution page → Report
Q37Moderate
Why does a squirrel cage induction motor not develop maximum starting torque?
View answer & solution
Correct answer: B. Rotor resistance is fixed and low
Quick explanation

Maximum torque at start (s = 1) needs R₂ = X₂. A cage rotor’s resistance is fixed and low, and no external resistance can be added, so its maximum torque occurs at a slip below 1.

T ∝ sR₂ / [R₂² + (sX₂)²] s_Tmax = R₂ / X₂
Verified · SRO Electrical deskSolution page → Report
Q38Moderate
This question uses a figure from the original paper. The figure is being added; the answer and explanation are already verified.
Which point or region represents the Pull-out Torque in the shown torque-speed characteristic of a 3-phase induction motor?
View answer & solution
Correct answer: D. Point c
Quick explanation

Pull-out (breakdown, maximum) torque is the peak of the torque-speed curve; in the paper’s figure the peak is labelled c.

s_m = R₂ / X₂
Verified · SRO Electrical deskSolution page → Report
Q39Moderate
A three-phase slip ring induction motor is preferred over a squirrel cage induction motor for which of the following application scenarios?
View answer & solution
Correct answer: C. When variable speed and high starting torque are required
Quick explanation

External rotor resistance can be added through the slip rings, giving high starting torque and limited speed control — so slip-ring motors suit those duties.

s_Tmax = R₂ / X₂ — raising R₂ moves maximum torque toward s = 1
Verified · SRO Electrical deskSolution page → Report

Induction Motors › Torque–Slip Characteristics (4)

Q40Moderate
Consider the following statements regarding Induction Motor Torque:
1. The maximum torque developed by an induction motor is independent of rotor resistance under constant supply conditions.
2. Increasing rotor resistance improves the starting torque of a slip-ring induction motor.
3. The slip corresponding to maximum torque is directly proportional to rotor resistance.
4. The electromagnetic torque becomes zero when the rotor reaches synchronous speed.
Which of the above statements is/are correct?
View answer & solution
Correct answer: D. All of the above
Quick explanation

For a given supply, the value of maximum torque is approximately independent of rotor resistance, while the slip at which it occurs is proportional to rotor resistance. Adding rotor resistance in a slip-ring motor can improve starting torque and shift maximum torque toward standstill. Key relation: s_max≈R₂/X₂ (referred form, simplified); T∝sR₂/(R₂²+(sX₂)²).

Exam focus: Rotor resistance shifts the torque-slip curve horizontally; it does not materially raise Tmax. Common trap: Maximum torque does not occur at synchronous speed because slip is zero there.

smax≈R₂/X₂ (referred form, simplified); T∝sR₂/(R₂²+(sX₂)²).
Verified · SRO editorial deskSolution page → Report
Q41Moderate
An induction motor develops maximum torque at slip = 0.2.
1. If rotor resistance is doubled, slip at maximum torque increases.
2. Maximum torque value remains unchanged with rotor resistance variation.
3. Starting torque increases with rotor resistance.
4. Maximum torque occurs at synchronous speed.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 3 only
Quick explanation

The torque-slip curve changes shape when rotor resistance is changed. The given initial s_max=0.2 is not needed to prove the qualitative relationships. Doubling R2 doubles the approximate slip at maximum torque until model limits; Tmax remains unchanged. Key relation: Approximate condition: s_max ∝ R2/Xeq. At s=1, starting torque rises as rotor resistance is increased toward the optimum R2≈Xeq.

Exam focus: Rotor resistance shifts the torque-slip curve horizontally, not vertically at Tmax. Common trap: Saying maximum torque occurs at synchronous speed; torque is zero at s=0.

Approximate condition: smax ∝ R2/Xeq. At s=1, starting torque rises as rotor resistance is increased toward the optimum R2≈Xeq.
Verified · SRO editorial deskSolution page → Report
Q42Moderate
For stable operation, what is the ratio of full-load torque to maximum torque usually in a 3-phase induction motor?
View answer & solution
Correct answer: C. Less than 1
Quick explanation

C — Less than 1. In normal stable operation the full-load torque is below the breakdown (maximum) torque, so T_FL/T_max < 1 — typically about 0.4–0.5.

Verified · SRO editorial deskSolution page → Report
Q43Hard
Which design feature of a three-phase induction motor will increase the ratio of full-load torque to maximum torque?
View answer & solution
Correct answer: C. Increasing the rotor resistance
Quick explanation

C — Increasing the rotor resistance. Higher rotor resistance shifts the maximum-torque slip upward while the maximum torque magnitude stays about the same, so the torque at full-load slip rises relative to Tmax.

Verified · SRO editorial deskSolution page → Report

Induction Motors › Equivalent Circuit (1)

Q44Easy
An induction motor can be said analogous to _________
View answer & solution
Correct answer: B. Transformer
Quick explanation

An induction motor is essentially a transformer with a rotating, short-circuited secondary. The stator acts like the primary and the rotor like the secondary, with power crossing the air gap electromagnetically.

f₂ = s f₁ Equivalent rotor resistance for power split: R₂'/s = R₂' + R₂'(1-s)/s
Verified · SRO editorial deskSolution page → Report

Induction Motors › Induction Generator (1)

Q45Easy
Which type of generator does not require a separate power source for excitation and operates at variable speeds?
View answer & solution
Correct answer: D. Induction generator
Quick explanation

D — Induction generator. It generates when driven above synchronous speed and needs no separate DC rotor-excitation supply, although magnetizing reactive power is still required.

Ns = 120f/P s = (Ns − Nr)/Ns < 0 during generation Ns = 120f/P s = (Ns − Nr)/Ns Nr > Ns gives s < 0
Verified · SRO editorial deskSolution page → Report

Induction Motors › Motor Starting (1)

Q46Moderate
What is the role of a star-delta starter in starting an induction motor?
View answer & solution
Correct answer: C. To reduce the supply voltage
Quick explanation

C — To reduce the supply voltage. At start the delta-rated winding is connected in star, so each phase gets V_L/√3; starting current and torque fall to one-third of direct-on-line values.

Verified · SRO editorial deskSolution page → Report

Induction Motors › No-Load Current (1)

Q47Moderate
Consider the following statements: Assertion: The no-load current of an induction motor is usually more than that of a transformer of similar rating. Reason: An induction motor can be considered as a generalized transformer. Of these statements:
View answer & solution
Correct answer: B. Both Assertion and Reason are true, but Reason is not the correct explanation of Assertion.
Quick explanation

An induction motor requires appreciable magnetizing current because its magnetic circuit includes an air gap, whose reluctance is much larger than the nearly closed iron path of a transformer. Hence its no-load current is generally higher. Both assertion and reason are true, but the reason statement as printed is not the complete/correct explanation expected by the item, leading to option B.

Large air-gap reluctance → higher magnetizing mmf/current
Verified · SRO editorial deskSolution page → Report

Induction Motors › Slip and Rotor Frequency (1)

Q48Easy
An induction motor operates at a slip of 5% with a supply frequency of 50 Hz.
1. Rotor frequency is approximately 2.5 Hz.
2. Rotor current frequency becomes zero at synchronous speed.
3. Rotor frequency equals supply frequency at standstill.
4. Rotor frequency is independent of slip.
Which of the above statements is/are correct?
View answer & solution
Correct answer: C. 1, 2 and 3 only
Quick explanation

Rotor-current frequency is proportional to slip: at standstill it equals supply frequency, and at synchronous speed it becomes zero. Rotor frequency fr=s f=0.05×50=2.5 Hz. At synchronous speed s=0, fr=0; at standstill s=1, fr=f. Key relation: s=(N_s−N)/N_s; f_r=s f_s.

Exam focus: Standstill: s=1; synchronous speed: s=0. Common trap: Rotor frequency is not independent of slip.

s=(Ns−N)/Ns; fr=s fs.
Verified · SRO editorial deskSolution page → Report

Induction Motors › Torque Characteristics (1)

Q49Moderate
What is the ratio of starting torque to maximum torque usually for a squirrel-cage induction motor?
View answer & solution
Correct answer: D. Less than 1
Quick explanation

D — Less than 1. In a normal squirrel-cage induction motor the starting torque is lower than the maximum (breakdown) torque, which occurs at a slip well below 1.

Verified · SRO editorial deskSolution page → Report

Synchronous Machines MCQs 11

Open Synchronous Machines page →
Q50Hard
Consider the following statements about torque in synchronous motors.
Statement I: The torque in a synchronous motor is produced only when the rotor is locked into synchronism.
Statement II: The torque is directly proportional to the sine of the load angle (δ).
Statement III: Synchronous motor develops starting torque proportional to the power input.
Statement IV: Maximum torque occurs at δ = 180°.
Which of the above statements are correct?
View answer & solution
Correct answer: D. Statements I & II only
Quick explanation

Steady torque exists only in synchronism, and for the basic cylindrical-rotor model T ∝ sin δ. A conventional synchronous motor has no inherent starting torque, and maximum torque occurs near δ = 90°, not 180°.

P = (3VE / X_s) sin δ T = P / ω_s ∝ sin δ T_max at δ ≈ 90°
Verified · SRO Electrical deskSolution page → Report
Q51Hard
Which set of statements correctly describes the steady state speed-torque characteristics of a three-phase synchronous motor?
(i) Runs at constant synchronous speed
(ii) Starting torque is zero
(iii) Torque increases significantly with slip
(iv) Not suitable for variable speed drives
(v) Maintains speed under varying loads
View answer & solution
Correct answer: C. (i), (ii), and (v) only
Quick explanation

A synchronous motor runs at synchronous speed, has zero inherent starting torque and holds speed as load changes. Torque depends on load angle, not slip, and converter-fed synchronous motors are used in variable-speed drives.

N_s = 120f / P Steady slip s = 0
Verified · SRO Electrical deskSolution page → Report

Synchronous Machines › Synchronous Motor (2)

Q52Easy
Consider the following statements regarding Synchronous Motor:
1. A synchronous motor is not self-starting and requires auxiliary means for starting.
2. It can operate at unity, lagging, or leading power factor depending on excitation.
3. Over-excited synchronous motors are used as synchronous condensers for power factor correction.
4. The speed of a synchronous motor varies significantly with load torque.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 3 only
Quick explanation

A conventional synchronous motor is not inherently self-starting. By adjusting field excitation it can operate at lagging, unity or leading power factor; over-excited operation is used for reactive-power support. Key relation: N_s=120f/P.

Exam focus: Excitation controls power factor; frequency and pole count set speed. Common trap: Load changes torque angle, not steady synchronous speed.

Ns=120f/P.
Verified · SRO editorial deskSolution page → Report
Q53Moderate
Compared with an induction motor, why does a synchronous motor usually operate at full load with higher efficiency?
View answer & solution
Correct answer: A. Absence of slip losses
Quick explanation

A — Absence of slip losses. A synchronous motor runs at zero slip, so there are no rotor slip (copper) losses of the induction-motor kind.

Verified · SRO editorial deskSolution page → Report

Synchronous Machines › Alternator Design (1)

Q54Moderate
These days alternators are designed to have larger air gaps for __________.
View answer & solution
Correct answer: D. All of the mentioned
Quick explanation

GPSC's final key accepts 'All of the mentioned'. A larger air gap reduces synchronous reactance and armature-reaction sensitivity, which improves stability/parallel operation; appropriate air-gap design also helps achieve a smoother magnetic-field distribution.

Larger air gap → magnetic reluctance ↑ → Xs generally ↓
Verified · SRO editorial deskSolution page → Report

Synchronous Machines › Alternator Dynamics (1)

Q55Easy
Damper windings in alternators help prevent which operational issue during sudden load changes?
View answer & solution
Correct answer: C. Hunting
Quick explanation

C — Hunting. Damper windings reduce the rotor oscillations that follow a sudden load change by producing a torque that opposes those oscillations.

Verified · SRO editorial deskSolution page → Report

Synchronous Machines › Alternator on Infinite Bus (1)

Q56Easy
The active power delivered by an alternator will _______ when the prime mover input is increased for the alternator connected to infinite bus bar.
View answer & solution
Correct answer: C. increase
Quick explanation

For an alternator connected to an infinite bus, bus voltage and frequency are fixed. Increasing prime-mover mechanical input increases torque angle δ and therefore increases the active power delivered to the bus.

P = (3VE/Xs) sinδ
Verified · SRO editorial deskSolution page → Report

Synchronous Machines › Input Current and Power Factor (1)

Q57Moderate
A 50 kW, 400 V, 3 phase synchronous motor is operating at full load with an efficiency of 90%. If the field current is adjusted to make its power factor 0.8 leading, estimate the armature current.
View answer & solution
Correct answer: C. 100 A
Quick explanation

C — 100 A approximately. Electrical input is 50/0.90 = 55.56 kW, giving line current 55,555.56/(√3 × 400 × 0.8) = 100.23 A.

IL = Pout/(η√3 VLcos φ) IL = 50,000/(0.90 × √3 × 400 × 0.8) = 100.23 A η = Pout/Pin Pin = 50,000/0.90 = 55,555.56 W Pin = √3 VLILcos φ IL = Pin/(√3 VLcos φ) IL = 55,555.56/(√3 × 400 × 0.8) IL = 100.23 A ≈ 100 A
Verified · SRO editorial deskSolution page → Report

Synchronous Machines › Power-Angle Characteristic (1)

Q58Hard
If the excitation of a synchronous motor is increased above normal, what is its effect on the maximum active (real) power developed by the motor?
View answer & solution
Correct answer: A. The developed power increases up to the stability (pull-out) limit.
Quick explanation

A — It increases up to the stability (pull-out) limit. With V and Xs constant, P = (VE/Xs) sinδ, so raising excitation E raises Pmax = VE/Xs.

Verified · SRO editorial deskSolution page → Report

Synchronous Machines › Rotating Magnetic Fields (1)

Q59Moderate
A synchronous machine has field winding on stator and polyphase armature winding on rotor. At steady state, which of the following is not true for its air gap field?
View answer & solution
Correct answer: B. Rotating at double the speed Ns w.r.t. rotor
Quick explanation

The final GPSC answer is B. A field winding placed on the stator produces an air-gap field stationary with respect to the stator. A rotor moving at synchronous speed sees that stationary field moving backward at Ns, not at 2Ns.

Nfield/stator = 0 Nrotor/stator = Ns Nfield/rotor = 0 - Ns = -Ns
Verified · SRO editorial deskSolution page → Report

Synchronous Machines › Synchronous Generator (1)

Q60Easy
A synchronous generator has 8 poles and rotates at 750 rpm.
1. Generated frequency is 50 Hz.
2. If speed increases to 1500 rpm, frequency becomes 100 Hz.
3. Frequency depends on speed and number of poles.
4. Frequency is independent of rotor speed.
Which of the above statements is/are correct?
View answer & solution
Correct answer: C. 1, 2 and 3 only
Quick explanation

A generator with more poles produces the same frequency at a lower mechanical speed; for fixed pole count, frequency is directly proportional to speed. f=PN/120. With P=8 and N=750 rpm, f=50 Hz; at 1500 rpm, f=100 Hz. Key relation: f=PN/120; N_s=120f/P.

Exam focus: Use rpm in the 120-factor formula. Common trap: Frequency is not independent of rotor speed in a synchronous generator.

f=PN/120; Ns=120f/P.
Verified · SRO editorial deskSolution page → Report

Electromechanical Energy Conversion MCQs 2

Electromechanical Energy Conversion › Field Energy (1)

Q61Moderate
A physical system of electromechanical energy conversion consists of a stationary part creating a magnetic field with electric energy input, and a moving part giving mechanical energy output. If the movable part is kept fixed, the entire electrical energy input will be _______
View answer & solution
Correct answer: A. Stored in the magnetic field
Quick explanation

In conventional electromagnetic energy-conversion devices, electrical input establishes magnetic flux in the coupling field, so energy is stored primarily in the magnetic field before being converted into mechanical work and/or returned electrically.

Electrical input = mechanical output + losses + ΔW_field Wm = ∫ B²/(2μ) dV
Verified · SRO editorial deskSolution page → Report

Electromechanical Energy Conversion › Torque Production (1)

Q62Moderate
Electromagnetic torque in rotating electrical machinery is present when ________
View answer & solution
Correct answer: A. Both stator and rotor windings carry current
Quick explanation

In a conventional doubly excited rotating machine, electromagnetic torque results from interaction between stator and rotor magnetic fields; hence both windings must be excited and carry current for this torque-production mechanism.

Te ∝ Φs Φr sinδ Te = ∂W'_{fld}/∂θ |_{currents constant}
Verified · SRO editorial deskSolution page → Report

Single-Phase Motors MCQs 2

Single-Phase Motors › Equivalent Circuit (1)

Q63Moderate
In the equivalent circuit of a single-phase induction motor, core loss is represented by which of the following?
View answer & solution
Correct answer: D. A resistance in parallel or series with the magnetising reactance
Quick explanation

D — A resistance with the magnetising reactance. Core loss (hysteresis + eddy current) is a real-power loss, so it is modelled by a resistance (R_c) in the magnetising branch.

Verified · SRO editorial deskSolution page → Report

Single-Phase Motors › Starting (1)

Q64Moderate
Consider the following statements: Assertion: Single-phase induction motor is not self-starting. Reason: Net rotating magnetic field produced by single-phase winding at standstill is zero. Of these statements:
View answer & solution
Correct answer: A. Both Assertion and Reason are true and Reason is the correct explanation of Assertion.
Quick explanation

At standstill a single-phase stator field can be resolved into equal forward and backward rotating fields. Their starting torques are equal and opposite, giving zero net starting torque; hence the motor is not self-starting. Both assertion and reason are true and the reason correctly explains the assertion: option A.

At standstill: Tf=Tb in opposite directions → Tnet=0
Verified · SRO editorial deskSolution page → Report

AC Machine Windings MCQs 1

AC Machine Windings › Machine Windings (1)

Q65Easy
Consider the following statements regarding AC Machine Windings:
1. Distributed windings are used in AC machines to reduce harmonic content and produce a nearly sinusoidal EMF waveform.
2. The pitch factor accounts for the effect of short-pitching of coils and usually reduces the magnitude of induced EMF.
3. Concentrated windings inherently produce a perfectly sinusoidal induced EMF waveform.
4. The winding factor is defined as the product of pitch factor and distribution factor in AC machines.
Which of the above statements is/are correct?
View answer & solution
Correct answer: C. 1, 2 and 4 only
Quick explanation

Distributed and short-pitched AC windings are deliberate design choices that improve waveform quality and suppress selected harmonics. Short pitching reduces the fundamental induced EMF slightly through pitch factor kp; distribution across slots introduces distribution factor kd. Key relation: k_w=k_p k_d; k_p=cos(α/2) for chording angle α.

Exam focus: Winding factor is normally less than 1. Common trap: A concentrated winding does not inherently guarantee a sinusoidal EMF.

kw=kp kd; kp=cos(α/2) for chording angle α.
Verified · SRO editorial deskSolution page → Report

Electrical Machines MCQ FAQs

How many Electrical Machines MCQs are on SarkariResultOut?

65 previous year Electrical Machines questions across 7 topics, each with the exam it was asked in, the verified answer and a step-by-step solution.

Which exams asked these Electrical Machines questions?

Supervisor Instructor · Part B Technical · 2026; GPSC DEE Electrical · DEE Master paper · 2026; GPSC AE Electrical · AE R&B · 2025 · Series M; RRB JE · CBT 2 Electrical · Shift 1; Vidyut Sahayak JE · Second tier · 2024 and more.

Can I download Electrical Machines MCQs as a PDF?

Yes. Tap “Download Electrical Machines PDF” — it is free after a quick sign-in and includes every answer and solution.