Synchronous Machines MCQ [Free PDF] – 11 Objective Questions with Answers

Every Synchronous Machines question asked in RRB JE, GPSC DEE Electrical, GPSC AE Electrical, Supervisor Instructor, GPSSB AAE Electrical, Vidyut Sahayak JE — solve, check instantly, then read the formula and exam tip.

11 PYQs9 subtopics6 examsUpdated 23 Oct 2026
Topic practice0/11✓ 0✗ 0
Q1Hard
Consider the following statements about torque in synchronous motors.
Statement I: The torque in a synchronous motor is produced only when the rotor is locked into synchronism.
Statement II: The torque is directly proportional to the sine of the load angle (δ).
Statement III: Synchronous motor develops starting torque proportional to the power input.
Statement IV: Maximum torque occurs at δ = 180°.
Which of the above statements are correct?
View answer & solution
Correct answer: D. Statements I & II only
Quick explanation

Steady torque exists only in synchronism, and for the basic cylindrical-rotor model T ∝ sin δ. A conventional synchronous motor has no inherent starting torque, and maximum torque occurs near δ = 90°, not 180°.

P = (3VE / X_s) sin δ T = P / ω_s ∝ sin δ T_max at δ ≈ 90°
Verified · SRO Electrical deskSolution page → Report
Q2Hard
Which set of statements correctly describes the steady state speed-torque characteristics of a three-phase synchronous motor?
(i) Runs at constant synchronous speed
(ii) Starting torque is zero
(iii) Torque increases significantly with slip
(iv) Not suitable for variable speed drives
(v) Maintains speed under varying loads
View answer & solution
Correct answer: C. (i), (ii), and (v) only
Quick explanation

A synchronous motor runs at synchronous speed, has zero inherent starting torque and holds speed as load changes. Torque depends on load angle, not slip, and converter-fed synchronous motors are used in variable-speed drives.

N_s = 120f / P Steady slip s = 0
Verified · SRO Electrical deskSolution page → Report

Synchronous Motor (2)

Q3Easy
Consider the following statements regarding Synchronous Motor:
1. A synchronous motor is not self-starting and requires auxiliary means for starting.
2. It can operate at unity, lagging, or leading power factor depending on excitation.
3. Over-excited synchronous motors are used as synchronous condensers for power factor correction.
4. The speed of a synchronous motor varies significantly with load torque.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 3 only
Quick explanation

A conventional synchronous motor is not inherently self-starting. By adjusting field excitation it can operate at lagging, unity or leading power factor; over-excited operation is used for reactive-power support. Key relation: N_s=120f/P.

Exam focus: Excitation controls power factor; frequency and pole count set speed. Common trap: Load changes torque angle, not steady synchronous speed.

Ns=120f/P.
Verified · SRO editorial deskSolution page → Report
Q4Moderate
Compared with an induction motor, why does a synchronous motor usually operate at full load with higher efficiency?
View answer & solution
Correct answer: A. Absence of slip losses
Quick explanation

A — Absence of slip losses. A synchronous motor runs at zero slip, so there are no rotor slip (copper) losses of the induction-motor kind.

Verified · SRO editorial deskSolution page → Report

Alternator Design (1)

Q5Moderate
These days alternators are designed to have larger air gaps for __________.
View answer & solution
Correct answer: D. All of the mentioned
Quick explanation

GPSC's final key accepts 'All of the mentioned'. A larger air gap reduces synchronous reactance and armature-reaction sensitivity, which improves stability/parallel operation; appropriate air-gap design also helps achieve a smoother magnetic-field distribution.

Larger air gap → magnetic reluctance ↑ → Xs generally ↓
Verified · SRO editorial deskSolution page → Report

Alternator Dynamics (1)

Q6Easy
Damper windings in alternators help prevent which operational issue during sudden load changes?
View answer & solution
Correct answer: C. Hunting
Quick explanation

C — Hunting. Damper windings reduce the rotor oscillations that follow a sudden load change by producing a torque that opposes those oscillations.

Verified · SRO editorial deskSolution page → Report

Alternator on Infinite Bus (1)

Q7Easy
The active power delivered by an alternator will _______ when the prime mover input is increased for the alternator connected to infinite bus bar.
View answer & solution
Correct answer: C. increase
Quick explanation

For an alternator connected to an infinite bus, bus voltage and frequency are fixed. Increasing prime-mover mechanical input increases torque angle δ and therefore increases the active power delivered to the bus.

P = (3VE/Xs) sinδ
Verified · SRO editorial deskSolution page → Report

Input Current and Power Factor (1)

Q8Moderate
A 50 kW, 400 V, 3 phase synchronous motor is operating at full load with an efficiency of 90%. If the field current is adjusted to make its power factor 0.8 leading, estimate the armature current.
View answer & solution
Correct answer: C. 100 A
Quick explanation

C — 100 A approximately. Electrical input is 50/0.90 = 55.56 kW, giving line current 55,555.56/(√3 × 400 × 0.8) = 100.23 A.

IL = Pout/(η√3 VLcos φ) IL = 50,000/(0.90 × √3 × 400 × 0.8) = 100.23 A η = Pout/Pin Pin = 50,000/0.90 = 55,555.56 W Pin = √3 VLILcos φ IL = Pin/(√3 VLcos φ) IL = 55,555.56/(√3 × 400 × 0.8) IL = 100.23 A ≈ 100 A
Verified · SRO editorial deskSolution page → Report

Power-Angle Characteristic (1)

Q9Hard
If the excitation of a synchronous motor is increased above normal, what is its effect on the maximum active (real) power developed by the motor?
View answer & solution
Correct answer: A. The developed power increases up to the stability (pull-out) limit.
Quick explanation

A — It increases up to the stability (pull-out) limit. With V and Xs constant, P = (VE/Xs) sinδ, so raising excitation E raises Pmax = VE/Xs.

Verified · SRO editorial deskSolution page → Report

Rotating Magnetic Fields (1)

Q10Moderate
A synchronous machine has field winding on stator and polyphase armature winding on rotor. At steady state, which of the following is not true for its air gap field?
View answer & solution
Correct answer: B. Rotating at double the speed Ns w.r.t. rotor
Quick explanation

The final GPSC answer is B. A field winding placed on the stator produces an air-gap field stationary with respect to the stator. A rotor moving at synchronous speed sees that stationary field moving backward at Ns, not at 2Ns.

Nfield/stator = 0 Nrotor/stator = Ns Nfield/rotor = 0 - Ns = -Ns
Verified · SRO editorial deskSolution page → Report

Synchronous Generator (1)

Q11Easy
A synchronous generator has 8 poles and rotates at 750 rpm.
1. Generated frequency is 50 Hz.
2. If speed increases to 1500 rpm, frequency becomes 100 Hz.
3. Frequency depends on speed and number of poles.
4. Frequency is independent of rotor speed.
Which of the above statements is/are correct?
View answer & solution
Correct answer: C. 1, 2 and 3 only
Quick explanation

A generator with more poles produces the same frequency at a lower mechanical speed; for fixed pole count, frequency is directly proportional to speed. f=PN/120. With P=8 and N=750 rpm, f=50 Hz; at 1500 rpm, f=100 Hz. Key relation: f=PN/120; N_s=120f/P.

Exam focus: Use rpm in the 120-factor formula. Common trap: Frequency is not independent of rotor speed in a synchronous generator.

f=PN/120; Ns=120f/P.