Transformers MCQ [Free PDF] – 16 Objective Questions with Answers

Every Transformers question asked in GPSC DEE Electrical, GPSC AE Electrical, Supervisor Instructor, GPSSB AAE Electrical, Vidyut Sahayak JE — solve, check instantly, then read the formula and exam tip.

16 PYQs13 subtopics5 examsUpdated 23 Oct 2026
Topic practice0/16✓ 0✗ 0

Transformer Efficiency (3)

Q1Moderate
Consider the following statements regarding Transformer Efficiency:
1. The maximum efficiency of a transformer occurs when copper losses are equal to core losses.
2. Transformer efficiency remains constant irrespective of the load connected to it.
3. All-day efficiency is an important performance metric for distribution transformers.
4. Efficiency generally increases with load up to a certain point before decreasing.
Which of the above statements is/are correct?
View answer & solution
Correct answer: B. 1, 3 and 4 only
Quick explanation

Transformer core loss is approximately constant at fixed voltage/frequency, while copper loss is I²R and therefore varies with the square of load. The competition between these losses creates a definite maximum-efficiency load point. Key relation: At x p.u. load: Pcu=x²Pcu,FL. Maximum η when x²Pcu,FL = Pi. All-day η = output energy (kWh)/input energy (kWh).

Exam focus: Remember: power transformer → ordinary efficiency; distribution transformer → all-day efficiency is frequently tested. Common trap: Saying efficiency is constant because transformer has no moving parts.

At × p.u. load: Pcu=x²Pcu,FL. Maximum η when x²Pcu,FL = Pi. All-day η = output energy (kWh)/input energy (kWh).
Verified · SRO editorial deskSolution page → Report
Q2Easy
A transformer has core loss = 500 W and full-load copper loss = 500 W.
1. Maximum efficiency occurs at full load condition.
2. At half load, copper loss becomes 125 W.
3. Efficiency at half load is lower than full load efficiency.
4. Condition for maximum efficiency is that copper loss equals core loss.
Which of the above statements is/are correct?
View answer & solution
Correct answer: B. 1, 2, 3 and 4
Quick explanation

At x p.u. load, transformer output is proportional to x while copper loss is proportional to x² and iron loss remains approximately constant. The given losses make the maximum-efficiency load x=sqrt(500/500)=1 p.u. Every statement follows numerically, so B is correct. Key relation: Pcu(x)=x²Pcu,FL. Here Pcu(0.5)=0.25×500=125 W. Maximum η: x²Pcu,FL=Pi → x=1.

Exam focus: If core loss equals full-load copper loss, maximum efficiency is at full load—an instant result. Common trap: Scaling copper loss linearly with load instead of with load squared.

Pcu(x)=x²Pcu,FL. Here Pcu(0.5)=0.25×500=125 W. Maximum η: x²Pcu,FL=Pi → x=1.
Verified · SRO editorial deskSolution page → Report
Q3Easy
A two-winding transformer operates at maximum efficiency when ____________.
View answer & solution
Correct answer: C. copper loss = iron loss
Quick explanation

C — Copper loss = iron loss. Maximum efficiency occurs at the load where the variable copper loss equals the constant iron (core) loss.

Verified · SRO editorial deskSolution page → Report

EMF Equation (2)

Q4Easy
What is the number of primary turns in a 200/1000V transformer if the emf per turn is 10V?
View answer & solution
Correct answer: C. 20
Quick explanation

The given transformer ratio is 200/1000 V and the emf per turn is 10 V. For the 200 V winding, N = E/(emf per turn) = 200/10 = 20 turns.

Emf per turn = E/N N = E / (emf per turn) N1 = 200/10 = 20 turns
Verified · SRO editorial deskSolution page → Report
Q5Moderate
In the EMF equation of a single-phase transformer E = 4.44 × f × N × φm, what does φm represent?
View answer & solution
Correct answer: D. Maximum magnetic flux in the transformer core
Quick explanation

D — Maximum magnetic flux in the core. In E = 4.44 f N φm, φm is the peak value of the sinusoidal core flux.

Verified · SRO editorial deskSolution page → Report

Autotransformer Applications (1)

Q6Easy
A 2000/1000/500 three winding transformer is to be used as auto transformer with supply of 3000V. Two loads of 1050 kVA at 3500 V and other one at 180 kVA at 1000 V. The total kVA supplied will be
View answer & solution
Correct answer: A. 1230 kVA
Quick explanation

The two specified loads are 1050 kVA and 180 kVA. The total apparent power supplied to the loads is therefore 1050 + 180 = 1230 kVA, matching option A.

Stotal = S₁ + S₂ = 1050 + 180 = 1230 kVA
Verified · SRO editorial deskSolution page → Report

Dry-Type Transformer (1)

Q7Easy
With reference to Dry-type Transformers in commercial buildings, consider the following:
1. They use air as the cooling and insulating medium instead of oil.
2. They are preferred for indoor installations due to reduced fire hazard.
3. They require frequent oil filtration and acidity testing.
Which of the statements given above is/are correct?
View answer & solution
Correct answer: A. 1 and 2 only
Quick explanation

Dry-type transformers use solid insulation and air/natural/forced-air cooling rather than flammable insulating oil. Their lower fire and environmental risk makes them suitable for indoor/commercial installations. Key relation: Cooling classes include AN/AF for dry-type designs.

Exam focus: Indoor fire-risk questions often favor dry-type transformers. Common trap: Oil maintenance belongs to oil-filled transformers, not dry-type units.

Verified · SRO editorial deskSolution page → Report

Ideal Transformer (1)

Q8Easy
A single-phase transformer operates with primary voltage of 230 V and secondary voltage of 115 V. It supplies a load current of 4 A. Assume ideal conditions.
1. The turns ratio between primary and secondary is 2.
2. The primary current is 2 A.
3. The output power delivered to the load is 460 W.
4. The input power is greater than output power under ideal conditions.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 3 only
Quick explanation

An ideal transformer conserves apparent power and relates voltages, turns and currents inversely. Turns ratio a=230/115=2. Output power=115×4=460 W. Key relation: V1/V2=N1/N2=a; I1/I2=N2/N1=1/a; ideal V1I1=V2I2.

Exam focus: Voltage ratio follows turns ratio; current ratio is inverse. Common trap: In an ideal transformer input power equals output power.

V1/V2=N1/N2=a; I1/I2=N2/N1=1/a; ideal V1I1=V2I2.
Verified · SRO editorial deskSolution page → Report

Isolation Transformer (1)

Q9Easy
The transformation ratio of an isolation transformer is usually:
View answer & solution
Correct answer: A. 1 : 1
Quick explanation

A — 1 : 1. A usual isolation transformer has equal primary and secondary turns so that it transfers approximately the same AC voltage while providing galvanic separation between the circuits.

Ideal transformer: V₂/V₁ = N₂/N₁. For equal turns, N₂ = N₁ and V₂/V₁ = 1.
Verified · SRO editorial deskSolution page → Report

OC and SC Tests (1)

Q10Easy
While conducting open circuit test and short circuit test on a transformer, status of low voltage and high voltage windings will be such that in ____________
View answer & solution
Correct answer: A. OC test − h.v. open, SC test − l.v. short-circuited
Quick explanation

In the usual transformer tests, the open-circuit test is performed by energizing the LV side and leaving the HV side open. The short-circuit test is usually performed by shorting the LV side and applying a reduced voltage to the HV side. This matches option A.

Verified · SRO editorial deskSolution page → Report

Parallel Operation (1)

Q11Moderate
Two single phase transformers A and B are operating in parallel having different impedance and identical x/r ratio. Then __________
View answer & solution
Correct answer: D. Both operate at same power factor
Quick explanation

If two transformers have different impedance magnitudes but identical X/R ratios, their impedance angles are equal. They may share unequal magnitudes of load, but the load-current phase angles are the same, so both operate at the same power factor.

ZA = |ZA|∠θ ZB = |ZB|∠θ (same X/R ⇒ same θ)
Verified · SRO editorial deskSolution page → Report

Three-Phase Transformer Connections (1)

Q12Moderate
Which of the following is not a valid three phase transformer connection?
View answer & solution
Correct answer: A. Dd1
Quick explanation

A — Dd1. A conventional delta–delta transformer connection does not provide the 30° displacement required by clock number 1.

Clock displacement = clock number × 30° Dd1 requires 30°; conventional Dd does not provide this displacement Phase displacement = 1 × 30° = 30°
Verified · SRO editorial deskSolution page → Report

Transformer Construction (1)

Q13Easy
What essential function is performed by the core in a single-phase transformer?
View answer & solution
Correct answer: D. It provides a magnetic path for flux linkage between the coils.
Quick explanation

D — It provides a magnetic path for flux linkage between the coils. The core gives a low-reluctance closed path to the alternating flux produced by the primary so that it links the secondary.

Verified · SRO editorial deskSolution page → Report

Transformer Core Materials (1)

Q14Easy
The steel used for transformer core has:
View answer & solution
Correct answer: D. High permeability
Quick explanation

D — High permeability. A high-permeability core provides a low-reluctance path and establishes the required flux with comparatively little magnetizing current.

ℜ = l/(μA) NI = Φℜ Magnetic reluctance ℜ = l/(μA) Φ = NI/ℜ
Verified · SRO editorial deskSolution page → Report

Transformer Tests (1)

Q15Easy
Consider the following statements regarding Transformer Testing:
1. The open-circuit test is conducted to determine core losses and magnetizing current at rated voltage conditions.
2. The short-circuit test is used to determine copper losses and equivalent impedance of the transformer.
3. In the open-circuit test, rated current flows in the primary winding during the test.
4. In the short-circuit test, a reduced voltage is applied to circulate rated current in the windings.
Which of the above statements is/are correct?
View answer & solution
Correct answer: A. 1, 2 and 4 only
Quick explanation

OC and SC tests separate transformer loss components without loading the transformer fully. OC emphasizes shunt/core behavior; SC emphasizes series/leakage behavior. Key relation: OC: P0 ≈ Pi(core). SC at rated current: Psc ≈ Pcu,FL; Zeq = Vsc/Isc; Req=Psc/Isc².

Exam focus: OC → rated voltage, small current, core loss. SC → rated current, small voltage, copper loss. Common trap: Confusing “rated voltage” in OC with “rated current”; the OC current is deliberately small.

OC: P0 ≈ Pi(core). SC at rated current: Psc ≈ Pcu,FL; Zeq = Vsc/Isc; Req=Psc/Isc².
Verified · SRO editorial deskSolution page → Report

Turns Ratio (1)

Q16Easy
In a transformer, if the primary coil has more turns than the secondary coil, the output voltage from the secondary coil will be ________.
View answer & solution
Correct answer: A. less than the input voltage
Quick explanation

A — Less than the input voltage. In an ideal transformer V2/V1 = N2/N1; with N1 > N2 it is a step-down transformer.

Verified · SRO editorial deskSolution page → Report