Illumination MCQs 9

Open Illumination page →

Illumination › Fluorescent Lamp (1)

Q1Easy
Which lamp provides diffuse illumination with good energy efficiency for indoor spaces such as railway waiting rooms?
View answer & solution
Correct answer: D. Fluorescent lamp
Quick explanation

D — Fluorescent lamp. Its long tube gives wide, diffuse, low-glare light with much better luminous efficacy than incandescent lamps.

Verified · SRO editorial deskSolution page → Report

Illumination › Halogen Lamp (1)

Q2Moderate
Which lamp provides a stable colour temperature and high colour rendering suitable for accurate colour reproduction in photography studios?
View answer & solution
Correct answer: D. Halogen lamp
Quick explanation

D — Halogen lamp. It is an improved incandescent source with a halogen regenerative cycle, giving high filament temperature, stable output, ~3200 K colour temperature and CRI close to 100.

Verified · SRO editorial deskSolution page → Report

Illumination › Illuminance (1)

Illumination › LED Lighting (1)

Q4Easy
Consider the following statements regarding LED lighting in industrial environments:
1. LEDs have higher luminous efficacy compared to High-Pressure Mercury Vapor lamps.
2. They offer a longer operational life, typically exceeding 50,000 hours.
3. The Color Rendering Index (CRI) of LEDs is generally poor for detailed industrial inspection tasks.
Which of the statements given above is/are correct?
View answer & solution
Correct answer: D. 1 and 2 only
Quick explanation

Modern industrial LEDs provide high luminous efficacy and long service life compared with older mercury-vapor technology. Suitable luminaires can also provide high CRI, so poor color rendering is not an inherent LED limitation; inspection areas can be designed with high-CRI LED sources. Key relation: Luminous efficacy=lumens/electrical watt.

Exam focus: Check efficacy, lifetime, CRI and glare together. Common trap: LED does not automatically mean poor CRI.

Luminous efficacy=lumens/electrical watt.
Verified · SRO editorial deskSolution page → Report

Illumination › Lighting Terminology (1)

Q5Easy
In street lighting, the term 'luminaire' refers to
View answer & solution
Correct answer: C. The complete lighting fixture including the lamp, housing and reflector
Quick explanation

A luminaire is the complete lighting unit/fixture: it includes the lamp or LED light source together with housing, optical components, electrical gear/driver and parts needed to distribute, position and protect the light source.

Luminaire = light source + optics + housing + control gear/driver + supporting fixture parts
Verified · SRO editorial deskSolution page → Report

Illumination › Mercury Vapour Lamp (1)

Illumination › Room Cavity Ratio (1)

Q7Moderate
A room is 120 feet by 60 feet with 16 feet ceiling. A luminaire is suspended 4 feet below the ceiling and the work plane is 4 feet above the floor. The value of room cavity ratio (RCR) is
View answer & solution
Correct answer: B. 1
Quick explanation

The luminaire is 4 ft below a 16-ft ceiling and the work plane is 4 ft above the floor, so cavity height is 8 ft. Room cavity ratio is RCR=5h(L+W)/(LW). Substituting h=8 ft, L=120 ft and W=60 ft gives RCR=1.0, matching option B.

RCR=5h(L+W)/(LW)=5×8×180/(120×60)=1.0
Verified · SRO editorial deskSolution page → Report

Illumination › Sodium Vapour Lamp (1)

Q8Moderate
What is the main function of the outer glass envelope in a sodium vapour lamp?
View answer & solution
Correct answer: B. To provide thermal insulation
Quick explanation

B — Thermal insulation. The evacuated outer envelope keeps the discharge tube hot enough to vaporise sodium and protects the inner tube; it is not the light source.

Verified · SRO editorial deskSolution page → Report

Illumination › Street Lighting (1)

Q9Easy
Which lamp technology is currently the most energy-efficient and widely adopted for new street lighting projects?
View answer & solution
Correct answer: D. Light Emitting Diode (LED)
Quick explanation

LED luminaires are the dominant high-efficiency choice for new street-lighting projects because they provide high luminous efficacy, long life, controllability, good optical directionality and lower maintenance compared with legacy discharge lamps.

Energy use ≈ lighting power × operating hours Higher luminaire efficacy (lm/W) → less electrical power for required light output
Verified · SRO editorial deskSolution page → Report

Building Automation & ELV MCQs 6

Open Building Automation & ELV page →

Building Automation & ELV › Audio-Visual Systems (1)

Q10Easy
Which of the following is typically NOT controlled by a building's Audio-Video (AV) system?
View answer & solution
Correct answer: D. The building's fire hydrant pressure
Quick explanation

An AV system typically controls presentation displays/projectors, screens, conferencing and audio/background-music equipment. Fire-hydrant pressure belongs to the fire-protection/mechanical monitoring system, not the AV system.

Verified · SRO editorial deskSolution page → Report

Building Automation & ELV › Building Management Systems (1)

Q11Easy
Which system is considered the central 'brain' for controlling and monitoring a building's mechanical and electrical equipment such as ventilation, lighting and power systems?
View answer & solution
Correct answer: C. Building Management System (BMS)
Quick explanation

A Building Management System (BMS) is the supervisory 'brain' used to monitor and control multiple building services such as HVAC, ventilation, lighting, pumps and electrical-energy systems through sensors, controllers and a central interface.

Sensors → controllers → communication network → BMS server/HMI → actuators
Verified · SRO editorial deskSolution page → Report

Building Automation & ELV › Energy Automation (1)

Q12Moderate
Choose correct option about the Smart Building Energy Automation (SBEA). Statement-1: It is based on development of complete building energy management system excluding battery management system. Statement-2: It manages and controls multiple-connected battery packs. It monitors the battery quantities SOC–SOH–DOD.
View answer & solution
Correct answer: A. Statement-1 is False, but Statement-2 is True
Quick explanation

Smart Building Energy Automation integrates monitoring, control, communication and optimization of building loads and may coordinate local generation and storage. The first statement excludes battery management from a complete energy-management system and is therefore not a correct description; the second statement is consistent with smart-building automation. The resulting combination is option A.

Verified · SRO editorial deskSolution page → Report

Building Automation & ELV › Network Topologies (1)

Q13Easy
In computer networking, which topology involves connecting all devices in a circular fashion?
View answer & solution
Correct answer: C. Ring
Quick explanation

In a ring topology, each network node is connected to two neighboring nodes so the links form a closed loop/circular path. Data travels around the ring according to the network's access/protocol design.

Verified · SRO editorial deskSolution page → Report

Building Automation & ELV › Network Topology and Media (1)

Q14Easy
Regarding Computer Networking in buildings:
1. A Star topology is the most common configuration for office Local Area Networks (LAN).
2. Fiber optic cables are preferred for long-distance building backbones due to their high bandwidth and immunity to EMI.
3. A Switch operates at the Physical layer (Layer 1) of the OSI model.
Which of the statements given above is/are correct?
View answer & solution
Correct answer: D. 1 and 2 only
Quick explanation

Modern office/building LANs commonly use switched Ethernet in a star topology. Fiber is favored for high-bandwidth or long backbone links and for immunity to electromagnetic interference. Key relation: Ethernet switch: primarily Layer 2; fiber backbone: high bandwidth and EMI immunity.

Exam focus: Distinguish a switch from a hub/repeater in OSI-layer questions. Common trap: A normal Ethernet switch is not principally a Layer-1 device.

Verified · SRO editorial deskSolution page → Report

Building Automation & ELV › Wireless Power Transfer (1)

Q15Easy
The principle of operation for most common wireless charging pads for mobile devices is based on
View answer & solution
Correct answer: B. Electromagnetic induction
Quick explanation

Most common phone charging pads transfer energy by electromagnetic induction between a transmitter coil in the pad and a receiver coil in the device, often with resonant compensation to improve coupling and efficiency.

e = −N dΦ/dt
Verified · SRO editorial deskSolution page → Report

Fire Alarm & Life Safety MCQs 4

Open Fire Alarm & Life Safety page →

Fire Alarm & Life Safety › Fire Alarm Systems (1)

Q16Easy
Regarding Fire Alarm Systems, consider the following:
1. Addressable fire alarm systems can pinpoint the exact location of the triggered detector.
2. Ionization smoke detectors are generally preferred for kitchen areas to avoid false alarms.
3. Manual call points (MCPs) allow occupants to manually initiate a fire alarmWhich of the statements given above is/are correct?
View answer & solution
Correct answer: C. 1 and 3 only
Quick explanation

Addressable fire-alarm systems assign an identity/address to each detector or module, enabling the panel to locate the initiating device. Kitchens are prone to nuisance alarms from cooking aerosols, so detector selection is application-specific and heat detection is often preferred over a sensitive ionization smoke detector.

Exam focus: Choose detector type for the environment, not just sensitivity. Common trap: Ionization smoke detectors are not generally the preferred kitchen solution for avoiding false alarms.

Addressable loop → device-level identification.
Verified · SRO editorial deskSolution page → Report

Fire Alarm & Life Safety › Fireman's Lift (1)

Q17Moderate
Consider the following statements regarding the Fireman’s Lift (as per NBC 2016):
1. It must be provided in all high-rise buildings exceeding 15 meters in height.
2. The lift must have a dedicated emergency power supply distinct from the normal building supply.
3. The lift must be accessible to the fire brigade and clearly marked as "Fireman’s Lift".Which of the statements given above is/are correct?
View answer & solution
Correct answer: D. 1, 2 and 3
Quick explanation

A fireman's/fire lift is a specially arranged lift for fire-service use in high-rise buildings, with protected controls/access, clear identification and emergency-power arrangements so it remains available during a fire when normal services may fail. Exact installation details should be checked against the applicable NBC/local adoption.

Exam focus: Treat fire lift as a life-safety system, not an ordinary passenger lift. Common trap: Do not omit emergency power/identification requirements.

Verified · SRO editorial deskSolution page → Report

Fire Alarm & Life Safety › Life Safety (1)

Q18Moderate
As per National Building Code (NBC 2016) the Refuge Area is defined as an area within the building for
View answer & solution
Correct answer: A. a temporary use during egress and generally serves a staging area which is protected from the effect of fire and smoke.
Quick explanation

NBC 2016 defines a refuge area as a designated safe area within a high-rise building where occupants can temporarily assemble or wait during an emergency before rescue or further evacuation. It is a life-safety provision, which is the description given by option A.

Refuge area = temporary safe holding area during emergency evacuation/rescue
Verified · SRO editorial deskSolution page → Report

Fire Alarm & Life Safety › Manual Initiation Devices (1)

Q19Easy
What is the main function of a Manual Call Point (MCP) in a fire alarm system?
View answer & solution
Correct answer: B. To allow a person to manually trigger the fire alarm
Quick explanation

A Manual Call Point (MCP) lets an occupant manually initiate the fire alarm after discovering a fire or dangerous condition. Activating it sends an alarm signal to the fire alarm control panel.

Person detects fire → operates MCP → fire alarm panel receives alarm → notification/control actions
Verified · SRO editorial deskSolution page → Report

Lifts & Escalators MCQs 3

Open Lifts & Escalators page →

Lifts & Escalators › Elevators (1)

Q20Easy
In an electromechanical lift system, what is the primary function of the governor?
View answer & solution
Correct answer: C. To activate the safety brake in case of overspeeding
Quick explanation

The lift governor is an overspeed-sensing safety device. If car speed exceeds its permitted value, the governor trips the safety mechanism so the car's safety gear/brake can grip the guide rails and stop the lift.

Overspeed → governor trips → safety gear/brake engages → car stops
Verified · SRO editorial deskSolution page → Report

Lifts & Escalators › Escalators (1)

Q21Easy
What is the typical angle of inclination for a commercial escalator as per general safety standards?
View answer & solution
Correct answer: B. 30 degrees
Quick explanation

A common commercial escalator inclination is about 30° to the horizontal. This provides a practical compromise between vertical rise, passenger comfort, safety and floor-space requirements.

Verified · SRO editorial deskSolution page → Report

Lifts & Escalators › Traction Elevators (1)

Q22Easy
In a traction lift, what is the function of the counterweight?
View answer & solution
Correct answer: B. It balances the weight of the lift car and a portion of its load to save energy
Quick explanation

The counterweight balances the lift car plus a designed fraction of rated load, reducing the traction motor torque and energy needed to move the system. It also helps maintain traction on the sheave.

Verified · SRO editorial deskSolution page → Report

Pumps & Water Supply MCQs 3

Open Pumps & Water Supply page →

Pumps & Water Supply › Pump Operation (1)

Q23Easy
Consider the following statements regarding Pumping Systems in buildings:
1. Net Positive Suction Head (NPSH) is a critical parameter to prevent cavitation in pumps.
2. Priming is necessary for centrifugal pumps if the pump is located above the liquid level (suction lift).
3. A booster pump is used to maintain constant pressure in high-rise water distribution systemsWhich of the statements given above is/are correct?
View answer & solution
Correct answer: D. 1, 2 and 3
Quick explanation

Centrifugal pumps require sufficient pressure at the suction to avoid local vaporization and cavitation; this is evaluated using NPSH. When a pump is above the liquid level, the casing/suction line must be primed because a centrifugal pump cannot normally evacuate air and establish suction by itself.

Exam focus: Cavitation questions: compare available and required NPSH. Common trap: Priming is unnecessary only for self-priming arrangements or when suction is already flooded.

Verified · SRO editorial deskSolution page → Report

Pumps & Water Supply › Pump Performance (1)

Q24Easy
What does the 'total head' of a pump represent?
View answer & solution
Correct answer: C. The total height to which a pump can move water, accounting for friction losses
Quick explanation

Pump total head represents the net energy added to the fluid per unit weight, expressed as an equivalent height of fluid. It accounts for elevation, pressure, velocity and system losses—not the pump's physical height.

Ph = ρgQH
Verified · SRO editorial deskSolution page → Report

Pumps & Water Supply › Pumps (1)

Q25Easy
Which type of pump is most commonly used for boosting water pressure in the water supply systems of tall buildings?
View answer & solution
Correct answer: C. Centrifugal pump
Quick explanation

Centrifugal pumps are most commonly used in building booster systems because they provide smooth continuous flow, are available in multistage high-head configurations and work well with variable-speed pressure control.

Verified · SRO editorial deskSolution page → Report

Standby & Emergency Power MCQs 3

Open Standby & Emergency Power page →

Standby & Emergency Power › Diesel Generator Sets (1)

Q26Easy
Consider the following regarding Diesel Generator (DG) sets:
1. An AMF (Auto Mains Failure) panel is required to automatically start the DG set when the main power fails.
2. The DG set room requires adequate ventilation to ensure combustion and to dissipate heat.
3. The Neutral of the DG set should never be earthed to avoid circulating currents.
Which of the statements given above is/are correct?
View answer & solution
Correct answer: A. 1 and 2 only
Quick explanation

Protective earthing provides a low-impedance path for fault current and stabilizes exposed conductive parts/neutral references. Earth resistance should be low enough to meet protection requirements and is checked periodically because soil/moisture/corrosion can change electrode performance. Key relation: Touch voltage and disconnection time depend on earthing and protective-device coordination.

Exam focus: Low earth resistance is desirable—not high resistance. Common trap: Never state that high earth resistance improves safety.

Verified · SRO editorial deskSolution page → Report

Standby & Emergency Power › Diesel Generators (1)

Q27Easy
What is the main purpose of a Diesel Generator (DG) set in a commercial building?
View answer & solution
Correct answer: C. To act as a backup power source during a grid outage
Quick explanation

A diesel generator set in a commercial building primarily provides backup/standby electrical power when the normal utility/grid supply fails. An automatic transfer system can start the DG and transfer selected essential loads.

Grid failure → DG start → voltage/frequency stabilize → ATS transfers essential loads
Verified · SRO editorial deskSolution page → Report

Standby & Emergency Power › Emergency Power (1)

Q28Easy
As per NBC 2016, which of the following is considered an essential load that must be connected to an emergency power system?
View answer & solution
Correct answer: C. Fire pumps and fire alarms
Quick explanation

Fire pumps and fire alarm systems are life-safety loads and must remain available during loss of normal power, so they are connected to emergency/standby power arrangements as required by building fire-safety design. General office loads and decorative lighting are not comparable essential loads.

Normal supply failure → emergency source/ATS → essential life-safety loads
Verified · SRO editorial deskSolution page → Report

Electric Welding MCQs 2

Q29Moderate
Which of the following statements about the atomic hydrogen arc welding process is correct?
View answer & solution
Correct answer: B. It employs two non-consumable tungsten electrodes to create an arc in a hydrogen atmosphere.
Quick explanation

Atomic hydrogen welding strikes an arc between two non-consumable tungsten electrodes in hydrogen. H₂ splits in the arc and recombines at the workpiece, releasing intense heat.

H₂ + energy → 2H 2H → H₂ + heat
Verified · SRO Electrical deskSolution page → Report

HVAC MCQs 2

HVAC › Air Distribution (1)

Q31Easy
A Variable Air Volume (VAV) system in HVAC is designed to
View answer & solution
Correct answer: B. Vary the airflow to a zone based on its temperature needs
Quick explanation

A VAV system primarily varies the quantity of supply air delivered to each zone according to its thermal demand while the central supply-air temperature is usually maintained within a controlled range. VAV boxes modulate airflow using dampers/controls.

Verified · SRO editorial deskSolution page → Report

HVAC › Refrigeration Cycle (1)

Q32Easy
Which component in a central air conditioning system is responsible for removing heat from the refrigerant?
View answer & solution
Correct answer: D. Condenser
Quick explanation

The condenser removes heat from the high-pressure refrigerant and rejects it to outdoor air or cooling water. During this process refrigerant changes from high-pressure vapor toward liquid before entering the expansion device.

Evaporator → Compressor → Condenser → Expansion valve → Evaporator Qcondenser = Qevaporator + Wcompressor
Verified · SRO editorial deskSolution page → Report

Building Power Distribution MCQs 1

Building Power Distribution › Busbar Trunking (1)

Q33Easy
With reference to Busbar Trunking Systems (BBT) in high-rise buildings:
1. They are used as an alternative to heavy cabling for vertical power distribution.
2. BBT systems offer better flexibility for adding "tap-off" points compared to cables.
3. They have higher voltage drops over long distances compared to copper cables of the same rating.
Which of the statements given above is/are correct?
View answer & solution
Correct answer: C. 1 and 2 only
Quick explanation

Busbar trunking distributes high current through enclosed rigid bus conductors and is widely used for vertical risers in high-rise buildings. Plug-in/tap-off units make load additions and reconfiguration easier than replacing large cable runs. Key relation: ΔV depends on I(R cosφ + X sinφ) and run length.

Exam focus: Tap-off flexibility is a key BBT advantage. Common trap: Do not assume busbar trunking always has higher voltage drop.

ΔV depends on I(R cosφ + X sinφ) and run length.
Verified · SRO editorial deskSolution page → Report

Electric Heating MCQs 1

Q34Moderate
An induction furnace operates at 10 kHz and is used to melt 100 kg of steel. If the efficiency is 60% and the energy required to melt steel is 1500 kWh/ton, what is the minimum energy input needed?
View answer & solution
Correct answer: A. 250 kWh
Quick explanation

The 100 kg charge is 0.1 ton, so the steel needs 0.1 × 1500 = 150 kWh of useful melting energy. At 60% efficiency, the electrical input must be 150 / 0.60 = 250 kWh.

m = 100 kg = 0.1 ton E_useful = 0.1 × 1500 = 150 kWh η = E_useful / E_input E_input = 150 / 0.60 = 250 kWh
Verified · SRO Electrical deskSolution page → Report

Utilisation & Building Services MCQ FAQs

How many Utilisation & Building Services MCQs are on SarkariResultOut?

34 previous year Utilisation & Building Services questions across 10 topics, each with the exam it was asked in, the verified answer and a step-by-step solution.

Which exams asked these Utilisation & Building Services questions?

GPSC AE Electrical · AE R&B · 2025 · Series M; GPSC DEE Electrical · DEE Master paper · 2026; Supervisor Instructor · Part B Technical · 2026; RRB JE · CBT 2 Electrical · Shift 1; GPSC DEE Electrical · DEE Electrical · 2024.

Can I download Utilisation & Building Services MCQs as a PDF?

Yes. Tap “Download Utilisation & Building Services PDF” — it is free after a quick sign-in and includes every answer and solution.