Controllers & Feedback MCQ [Free PDF] – 5 Objective Questions with Answers

Every Controllers & Feedback question asked in GPSC DEE Electrical, GPSC AE Electrical — solve, check instantly, then read the formula and exam tip.

5 PYQs4 subtopics2 examsUpdated 23 Oct 2026
Topic practice0/5✓ 0✗ 0

PI Controller (2)

Q1Moderate
Assertion (A): A PI controller increases the order of the system by units but decreases the steady state error.
Reason (R): A PI controller introduces a pole at either the origin or at a desired points on the negative real axis.
View answer & solution
Correct answer: C. (A) is true but (R) is false
Quick explanation

A PI controller adds an integrator pole at the origin and a finite zero, increasing system type and reducing/eliminating steady-state error for appropriate inputs. The assertion is therefore true. The reason is false because a PI controller's added pole is specifically at the origin; the finite negative-real-axis point is the controller zero, not an arbitrary added pole.

GPI(s)=Kp + Ki/s =Kp(s+Ki/Kp)/s Pole: s=0 Zero: s=−Ki/Kp
Verified · SRO editorial deskSolution page → Report
Q2Moderate
Read the following statements in the context of a PI controller used to control a first order LTI system.
Statement 1: The order of overall closed loop system becomes higher than the open loop system.
Statement 2: Increasing integral gain makes the overall system to have higher damping.
Choose the correct options from the following:
View answer & solution
Correct answer: B. Statement 1 is correct but statement 2 is incorrect.
Quick explanation

A PI controller introduces an integrator 1/s, so a first-order plant normally produces a second-order closed-loop characteristic equation: Statement 1 is true. For a standard plant K/(τs+1) with fixed K_p, ζ = (1 + KK_p)/(2√(τKK_i)); increasing K_i reduces ζ, so Statement 2 is false.

C(s) = Kp + Ki/s = (Kps + Ki)/s G(s) = K/(τs + 1) Characteristic equation: τs² + (1 + KKp)s + KKi = 0 ζ = (1 + KKp)/(2√(τKKi)) G(s) = K/(τs + 1) C(s) = Kp + Ki/s C(s) = (Kps + Ki)/s 1 + K(Kps + Ki)/[s(τs + 1)] = 0 s(τs + 1) + K(Kps + Ki) = 0 τs² + (1 + KKp)s + KKi = 0 s² + [(1 + KKp)/τ]s + KKi/τ = 0 s² + 2ζωns + ωn² = 0 ωn = √(KKi/τ) ζ = (1 + KKp)/(2√(τKKi)) Ki ↑ ⇒ √Ki ↑ ⇒ ζ ↓ (K, τ, Kp fixed)
Verified · SRO editorial deskSolution page → Report

Negative Feedback (1)

Q3Moderate
Read the following statements in the context of negative feedback system.
Statement 1: Negative feedback always makes the overall system response stable.
Statement 2: Negative feedback system may improve the system’s robustness towards parametric uncertainties.
Choose the correct option from the following:
View answer & solution
Correct answer: C. Statement 2 is correct and statement 1 is incorrect.
Quick explanation

Statement 1 is false because negative feedback does not always guarantee stable closed-loop poles. Statement 2 is true because negative feedback can reduce parameter sensitivity; for a standard loop, S = 1/[1 + G(s)H(s)]. Therefore option C is correct.

T(s) = G(s)/[1 + G(s)H(s)] Characteristic equation: 1 + G(s)H(s) = 0 Sensitivity: S = 1/[1 + G(s)H(s)] T(s) = G(s)/[1 + G(s)H(s)] Characteristic equation: 1 + G(s)H(s) = 0 S = 1/[1 + G(s)H(s)]
Verified · SRO editorial deskSolution page → Report

PID Controller (1)

Q4Moderate
Consider the following statements regarding PID Controller Design:
1. Proportional control reduces rise time.
2. Integral control eliminates steady-state error.
3. Derivative control improves damping.
4. PID control guarantees stability always.
Which of the above statements is/are correct?
View answer & solution
Correct answer: C. 1, 2 and 3 only
Quick explanation

Proportional action generally speeds response but leaves finite error; integral action raises low-frequency gain and can eliminate step steady-state error; derivative action adds predictive damping and can reduce overshoot. None of these by itself guarantees stability for every plant/tuning. Key relation: u(t)=K_p e + K_i∫e dt + K_d de/dt.

Exam focus: I fixes offset; D improves damping; P sets overall response strength. Common trap: PID is not an unconditional stability guarantee.

u(t)=Kp e + Ki∫e dt + Kd de/dt.
Verified · SRO editorial deskSolution page → Report

Role of Controller (1)

Q5Easy
What is the need for a controller?
View answer & solution
Correct answer: C. Modify control signals
Quick explanation

A controller processes the error/control information and modifies the control signal so the plant responds according to desired performance requirements. It may amplify, integrate, differentiate, shape or otherwise compensate the signal.

u(t)=Controller{e(t)} u=Kp e+Ki∫e dt+Kd de/dt